Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
depending on configuration
Max. process pressure (static)
depending on the configuration up to 500 bar
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
Çubuk termovel ile birlikte veya yerinde termovel ile kullanılmak üzere modüler endüstriyel RTD veya TC termometre. Gelişmiş doğruluk ve güvenilirlik için Endress+Hauser sıcaklık transmiterleri ile kullanılabilir - çıkışları ve iletişim protokollerini seçerek kolay özelleştirme. İsteğe bağlı olarak Bluetooth® bağlantısı ile kullanılabilir. iTHERM QuickNeck gibi en son yeniliklere ve iTHERM QuickSens ve iTHERM StrongSens gibi sıcaklık sensörü teknolojilerine sahip termometre.
Evrensel uygulama aralığı
Ölçüm aralığı: -200 ila +1.100 °C (-328 ila +2.012 °F)
500 bar'a (7.252 psi) kadar basınç aralığı
60g'a kadar titreşime dayanıklı sensör cihazı
Geliştirilmiş bakım kolaylığı (proses durdurulmadan sensör değişimi), ölçüm noktasının kolay ve güvenli yeniden kalibrasyonu
Avantajlar
İkinci bir proses sızdırmazlığı ile arıza durumunda sinyal bildirimi sağlayan sistem, cihazın sağlık durumuna dair önemli bilgiler sunar
iTHERM QuickSens: optimum proses kontrolü için 1,5 sn'lik en hızlı yanıt süreleri
iTHERM StrongSens: üstün tesis güvenliği için eşsiz titreşim direnci (> 60g)
iTHERM QuickNeck: basit, aletsiz yeniden kalibrasyon sayesinde maliyet ve zaman tasarrufu
Bluetooth® bağlantısı (isteğe bağlı)
Uluslararası sertifikasyon: ATEX, IECEx, CSA C/US ve CCC'ye göre patlama koruması
Iplom SpA, hassas 3D sıcaklık profili çıkarma yöntemiyle rafineri prosesini optimize ederek hem katalizör ömrünü uzatmayı hem de hidrojenle kükürt giderme (HDS) uygulamasındaki güvenliği artırmayı hedefliyor.
metric style modular temperature assembly universal range of application suitable for hazardous areas suitable for high process pressures with neck or iTHERM QuickNeck incl. thermowell / protection tube (metal) or to be installed into thermowell can be used with iTHERM StrongSens
Thermowell / protection tube
barstock (drilled) or to be used with thermowell
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
16 mm (0,63") 18 mm (0,71") 19 mm (0,75") 19,5 mm (0,77") 20 mm (0,79") 22,2 mm (0,87") 24 mm (0,95") 25 mm (0,98") 25,4 mm (1,0") 26 mm (1,02") 27 mm (1,06") 30 mm (1,18") 33,4 mm (1,31")
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
Max. process pressure (static)
depending on the configuration up to 500 bar
Accuracy
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
depending on configuration
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
ATEX II3G Ex ec IIC T6, II3D CSA C/US General Purpose CSA C/US IS, NI I/1+2/A-D CSA C/US XP, NI, DIP I, II, III/1+2/A-G CSA C/US DIP II, III / 1/E-G EAC 0Ex ia IIC T6...T1 Ga X EAC Ga/Gb Ex d IIC T6...T1 X EAC Ex ta/tb IIIC 85oC...450oC Da/Db X EAC Ga/Gb Ex ia IIC T6...T1 X EAC 0Ex ia IIC T6...T1 Ga X, Ex ia IIIC 85oC...450oC Da/Db X EAC Ga/Gb Ex d IIC T6...T1 X, Ex ta/tb IIIC 85oC...450oC Da/Db X INMETRO Ex ia IIC T6 Ga/Gb, Ex ia IIIC Da/Db INMETRO Ex d IIC T6 Ga/Gb, Ex tb IIIC Da/Db INMETRO Ex nA IIC T6 Gc CCC Ex ia IIC T6 Ga/Gb CCC Ex d IIC T6 Ga/Gb, Ex tD A20/A21 CCC Ex tD A20/A21 CCC Ex nA IIC T6 Gc UK II1/2G Ex ia IIC T6 Ga/Gb, II1/2D Ex ia IIIC Da/Db UK II3G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc UK II1/2G Ex db IIC T6 Ga/Gb, II1/2D Ex ta/tb IIIC Da/Db ATEX IECEx II1/2D Ex ta/tb IIIC Da/Db ATEX IECEx II1/2G Ex ia IIC T6 Ga/Gb ATEX IECEx II1/2G Ex ia IIC T6, II1/2D ATEX IECEx II1/2G Ex db IIC T6, II1/2D NEPSI Ex ia IIC T1...T6 Ga/Gb, Ex ia IIIC T85oC...T450oC Db NEPSI Ex d IIC T6 Ga/Gb, Ex tD A20/A21 NEPSI Ex tb IIIC Da/Db NEPSI Ex ec IIC T6 Gc
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Tarayıcı deneyiminizi iyileştirmek, site işlevselliğini optimize etmek adına istatistikleri toplamak ve size uygun reklam ve içerikler göstermek için çerezleri kullanıyoruz.
"Tümünü kabul et" seçeneği ile çerez kullanımımıza rıza göstermiş olursunuz.
Daha fazla ayrıntı için lütfen göz atın: Çerez Politikamız .