Özelliklere genel bakış
-
Accuracy
+/- 3 mm or +/- 0.2 % of set measuring range
-
Process temperature
-20 °C...+60 °C
(-4 °F...+140 °F) -
Process pressure / max. overpressure limit
0.7 bar...3 bar abs
(10 psi ...44 psi) -
Max. measurement distance
Sensor 1-1/2": 2 m (6.6 ft)
Sensor 2": 3.5 m (11 ft) -
Main wetted parts
PP/EPDM
Uygulama alanı
The range of applications extends from monitoring levels in sewage treatment plants and process water tanks to applications for loading, storage and buffer tanks. FMU30 ultrasonic sensor offers proven software algorithms and all warning and alarm messages are shown on the four-line plain text display and guarantee fast remedy of problems. The envelope curve can also be shown on the display. As the analysis results are displayed directly on-site, this ensures quick and accurate error diagnostics.
Two-wire instrument for continuous non-contact level and flow measurement.
Process connection: Thread
Temperature: -20 to +60°C (-4 to +140°F)
Pressure: +0.7 to +3bar (+10 to +44psi)
Maximum measuring distance:
Sensor 1½" for liquids 5m (16ft) and for bulk solids 2m (6.6ft),
Sensor 2" for liquids 8m (26ft)and for bulk solids 3.5m (11ft)Blocking distance:
Sensor 1½" 0.25m (0.8ft),
Sensor 2" 0.35m (1.15ft)International explosion protection certificates
Avantajlar
Quick and simple commissioning via menu-guided onsite operation with four-line plain text display, 7 languages selectable
Envelope curves on the on-site display for simple diagnosis
Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
Non-contact measurement method minimizes service requirements
Installation possible from thread G 1½ or 1½ NPT upwards
Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Videolar
Fundamental seçim
-
Basit ürünler
- Seçmesi, kurması ve çalıştırması kolay
Teknik mükemmellik
Sadelik
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri | Teknik mükemmellik | Sadelik |
---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
Önceki seri
-
-
Kullanma Talimatı (BA)
Prosonic T FMU30
İngilizce versiyonu - 02/2014
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
EN TR 14/02/201404/04/201216/02/2010Dil:
İngilizce
Versiyon:
14/02/2014
Dosya boyutu:
3 MB
Dosya adı:
BA00387FEN_1414.pdf
-
-
-
Teknik Bilgiler (TI)
Ultrasonic Level Measurement
İngilizce versiyonu - 02/2014
Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials
EN TR 14/02/201416/01/201331/03/201116/02/2010Dil:
İngilizce
Versiyon:
14/02/2014
Dosya boyutu:
2.1 MB
Dosya adı:
TI00440FEN_1514.pdf
-
-
-
Teknik Bilgiler (TI)
Ultrasonic Level Measurement
Compact transmitters for non-contact level measurement of fluids, pastes
and coarse bulk materialsEN TR 14/02/201416/01/201331/03/201116/02/2010Dil:
İngilizce
Versiyon:
14/02/2014
Dosya boyutu:
2.1 MB
Dosya adı:
TI00440FEN_1514.pdf
-
-
-
Kullanma Talimatı (BA)
Prosonic T FMU30
Compact transmitters for non-contact level measurements of fluids,
pastes and coarse bulk materialsEN TR 14/02/201404/04/201216/02/2010Dil:
İngilizce
Versiyon:
14/02/2014
Dosya boyutu:
3 MB
Dosya adı:
BA00387FEN_1414.pdf
-
-
-
Kullanma Talimatı (BA)
Prosonic T FMU30
Compact transmitters for non-contact level measurements of fluids,
pastes and coarse bulk materialsEN TR 14/02/201404/04/201216/02/2010Dil:
İngilizce
Versiyon:
14/02/2014
Dosya boyutu:
3.2 MB
Dosya adı:
BA00388FEN_1414.pdf
-
-
-
Kısa Talimat (KA)
Ultrasonic Level Measurement
Prosonic T FMU30
EN TR 16/02/2010Dil:
İngilizce
Versiyon:
16/02/2010
Dosya boyutu:
138.6 KB
Dosya adı:
KA290FA2_1209.pdf
-
-
-
Kısa Talimat (KA)
KA Prosonic T FMU30
Ultrasonik ölçüm teknolojisi
EN TR 01/12/2022Dil:
Türkçe
Versiyon:
01/12/2022
Dosya boyutu:
488.4 KB
Dosya adı:
KA01638FTR_0122-00.pdf
-
-
-
Kısa Talimat (KA)
Prosonic T FMU30 Brief Operating Instructions
Compact transmitters for non-contact level measurements of fluids,
pastes and coarse bulk materialsEN TR 14/02/201404/11/201108/09/201116/02/2010Dil:
İngilizce
Versiyon:
14/02/2014
Dosya boyutu:
1.8 MB
Dosya adı:
KA01054FEN_1514.pdf
-
-
-
Kurulum talimatları (EA)
Sensor for FMU30 Installation instruction
Prosonic T FMU30
EN TR 12/04/2012Dil:
İngilizce
Versiyon:
12/04/2012
Dosya boyutu:
261.6 KB
Dosya adı:
EA0032FA2_0210.pdf
-
-
-
Kurulum talimatları (EA)
Electronics for FMU30 Installation instruction
Prosonic T FMU30 - exchange of electronics
EN TR 12/04/2012Dil:
İngilizce
Versiyon:
12/04/2012
Dosya boyutu:
210 KB
Dosya adı:
EA0030FA2_0210.pdf
-
-
-
Kurulum talimatları (EA)
Display for FMU30 Installation instruction
Prosonic T FMU30
EN TR 12/04/2012Dil:
İngilizce
Versiyon:
12/04/2012
Dosya boyutu:
164.8 KB
Dosya adı:
EA0031FA2_0210.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Prosonic T FMU30
II 1/2 G Ex ia IIC T5 Ga/Gb
Dil:
İngilizce
Versiyon:
05/07/2021
Dosya boyutu:
398.2 KB
Dosya adı:
XA02542FEN_0121-00.pdf
-