Özelliklere genel bakış
-
Process temperature
-80 °C ... +200 °C
(-112 °F ... +392 °F) -
Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vacuum ... 1450 psi)
Uygulama alanı
Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials - this guarantees a high safety standard.
For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.
Process connections: Flanges, threads, special hygienic process connections
Temperature: -80 to +200°C (-112 to +392°F)
Pressure: Vacuum to +100bar (vacuum to +1,450psi)
Sensor length: 12m (39ft)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval
Avantajlar
Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a button
Reliable and safe measurement due to active build-up compensation
Reliable and universal application thanks to wide range of certificates and approvals
Short reaction time
Material in contact with the process made of corrosion-resistant and FDA-listed materials
Two-stage overvoltage protection
No need for recalibration after replacing electronics
Videolar
Lean seçim
-
Standart ürünler
- Güvenilir, sağlam ve az bakım gerektiren
Teknik mükemmellik
Sadelik
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri | Teknik mükemmellik | Sadelik |
---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
Önceki seri
-
-
Teknik Bilgiler (TI)
TI Liquicap M FTI52
İngilizce versiyonu - 09/2024
Capacitance
EN TR 05/09/202425/09/2023Dil:
İngilizce
Versiyon:
05/09/2024
Dosya boyutu:
1.5 MB
Dosya adı:
TI01542FEN_0224-00.pdf
-
-
-
Teknik Bilgiler (TI)
TI Weld-in adapter, process adapter and flanges
İngilizce versiyonu - 03/2024
Level, pressure and temperature measurement
EN TR 25/03/202415/09/202328/10/202130/07/202119/06/2020Dil:
İngilizce
Versiyon:
25/03/2024
Dosya boyutu:
1.1 MB
Dosya adı:
TI00426FEN_2524.pdf
-
-
-
Teknik Bilgiler (TI)
TI Liquicap M FTI52
Capacitance
EN TR 05/09/202425/09/2023Dil:
İngilizce
Versiyon:
05/09/2024
Dosya boyutu:
1.5 MB
Dosya adı:
TI01542FEN_0224-00.pdf
-
-
-
Teknik Bilgiler (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN TR 25/03/202415/09/202328/10/202130/07/202119/06/2020Dil:
İngilizce
Versiyon:
25/03/2024
Dosya boyutu:
1.1 MB
Dosya adı:
TI00426FEN_2524.pdf
-
-
-
Teknik Bilgiler (TI)
Technical Information Liquicap M FTI51, FTI52
Capacitance
Point level switch for liquidsEN TR 22/06/201712/01/201105/03/201006/11/200821/09/2007Dil:
İngilizce
Versiyon:
22/06/2017
Dosya boyutu:
1.8 MB
Dosya adı:
TI00417FEN_1417.pdf
-
-
-
Kullanma Talimatı (BA)
BA Liquicap M FTI52
Capacitance
EN TR 05/09/202425/09/2023Dil:
İngilizce
Versiyon:
05/09/2024
Dosya boyutu:
2.5 MB
Dosya adı:
BA02032FEN_0224-00.pdf
-
-
-
Kullanma Talimatı (BA)
Operating Instructions Liquicap M FTI51, FTI52
Capacitance point level switch
EN TR 22/06/201712/01/201105/03/201005/10/200824/08/2006Dil:
İngilizce
Versiyon:
22/06/2017
Dosya boyutu:
1.7 MB
Dosya adı:
BA00299FEN_1417.pdf
-
-
-
Kısa Talimat (KA)
Liquicap M FTI52
Kapasitif limit seviye sivici
EN TR 01/09/2021Dil:
Türkçe
Versiyon:
01/09/2021
Dosya boyutu:
865.4 KB
Dosya adı:
KA01477FTR_0120.pdf
-
-
-
Kurulum talimatları (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN TR 09/08/2012Dil:
İngilizce
Versiyon:
09/08/2012
Dosya boyutu:
158.7 KB
Dosya adı:
EA01049FA2_01.12.pdf
-
-
-
Kurulum talimatları (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN TR 11/08/201409/08/2012Dil:
İngilizce
Versiyon:
11/08/2014
Dosya boyutu:
164.3 KB
Dosya adı:
EA01048FA2_0214.pdf
-
-
-
Kurulum talimatları (EA)
Cover for housing F27 Installation instruction
Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
EN TR 11/08/201416/01/201409/08/2012Dil:
İngilizce
Versiyon:
11/08/2014
Dosya boyutu:
136.4 KB
Dosya adı:
EA01047FA2_0314.pdf
-
-
-
Kurulum talimatları (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, SoliphantM, Liquicap M, Solicap M/S
EN TR 11/08/201409/08/2012Dil:
İngilizce
Versiyon:
11/08/2014
Dosya boyutu:
134.4 KB
Dosya adı:
EA01046FA2_0214.pdf
-