Özelliklere genel bakış
-
Measuring range
1 µS/cm to 500 mS/cm
-
Process temperature
-5 to 120 °C (23 to 248 °F)
Sterilization: max. 140 °C at 6 bar for max. 45 min
(Max. 284 °F at 87 psi for max. 45 min) -
Process pressure
17 bar abs at 20 °C (247 psi at 68 °F)
9 bar abs at 120 °C (131 psi at 248 °F)
Uygulama alanı
Memosens CLS82E is a high-end, hygienic sensor for applications with widely varying conductivity values. It enables reliable monitoring of core processes as well as final rinse with only one sensor. FDA compliance and a small, compact design ensure the perfect fit to your processes. With Memosens 2.0 digital technology, CLS82E allows for extended storage of process and sensor data facilitating lab calibration and predictive maintenance and providing the perfect basis for enhanced IIoT services.
Memosens CLS82E measures conductivity in applications that need to cover a wide measuring range as in:
Phase separation
Downstream processing
Fermentation
Chromatography
Ultrafiltration
Final rinse in pharma applications
With its international explosion protection approvals, such as ATEX, FM, CSA and NEPSI, the digital sensor is suitable for hazardous area use.
Avantajlar
Hygienic design and materials certified and approved by EHEDG, 3-A and FDA ensure compliance with GMP requirements. The sensor is sterilizable and autoclavable.
Absolute loop safety thanks to Memosens and unique detection of build-up on electrodes.
The broad measuring range enables monitoring of core processes and final rinse with one sensor, saving costs.
Its compact design makes the sensor suitable for small pipe diameters and narrow, space-limited installations.
Quality certificate stating the individual cell constant allows precise adjustment of the measurement.
Non-contact, inductive signal transmission ensures high process and data integrity.
IIoT ready: Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Videolar
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri | Teknik mükemmellik | Sadelik |
---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
Extended seçim
-
Üst düzey ürünler
- Son derece fonksiyonel ve uygun
Teknik mükemmellik
Sadelik
Önceki seri
-
-
Teknik Bilgiler (TI)
TI Memosens CLS82E
İngilizce versiyonu - 05/2024
Hygienic conductivity sensor Digital with Memosens technology
EN TR 07/05/202420/08/202124/02/2021Dil:
İngilizce
Versiyon:
07/05/2024
Dosya boyutu:
568.4 KB
Dosya adı:
TI01529CEN_0324-00.pdf
-
-
-
Teknik Bilgiler (TI)
TI Memosens CLS82E
Hygienic conductivity sensor
Digital with Memosens technologyEN TR 07/05/202420/08/202124/02/2021Dil:
İngilizce
Versiyon:
07/05/2024
Dosya boyutu:
568.4 KB
Dosya adı:
TI01529CEN_0324-00.pdf
-
-
-
Kullanma Talimatı (BA)
Memosens CLS82E
Hijyenik iletkenlik sensörü
Memosens teknolojisine sahip dijitalEN TR 18/11/202120/08/202124/02/2021Dil:
Türkçe
Versiyon:
18/11/2021
Dosya boyutu:
500.4 KB
Dosya adı:
BA02027CTR_0321-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
XA Memosens CLS15E, CLS16E, CLS21E, CLS82E
Digital conductivity sensors with Memosens technology
INMETRO Ex ia IIC T3/T4/T6 GaEN TR 04/11/202423/11/2020Dil:
İngilizce
Versiyon:
04/11/2024
Dosya boyutu:
502.8 KB
Dosya adı:
XA02078CEN_0224-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
XA Memosens CLS15E, CLS16E, CLS21E, CLS82E
Digital conductivity sensors with Memosens technology
CSA C/US IS Cl. 1 Div. 1 GP A-D T3/T4/T6 + CSA C/US IS Cl. 1 Zone 0 AEx
ia IIC T3/T4/T6EN TR 05/04/202431/05/2021Dil:
İngilizce
Versiyon:
05/04/2024
Dosya boyutu:
580 KB
Dosya adı:
XA02079CEN_0224-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
XA Memosens CLS15E, CLS16E, CLS21E, CLS82E
Digital conductivity sensors with Memosens technology
NEPSI Ex ia IIC T3/T4/T6 GaEN TR 08/04/202417/08/2021Dil:
İngilizce
Versiyon:
08/04/2024
Dosya boyutu:
591.8 KB
Dosya adı:
XA02543CEN_0224-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Memosens CLS15E, CLS16E, CLS21E, CLS82E
EAC Ex 0Ex ia IIC T3/T4/T6 Ga X
Safety instructions for electrical apparatus in explosion-hazardous
areasEN TR 21/09/2022Dil:
İngilizce
Versiyon:
21/09/2022
Dosya boyutu:
489.2 KB
Dosya adı:
XA02081CEN_0122-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
XA Memosens CLS15E, CLS16E, CLS21E, CLS82E
Digital conductivity sensors with Memosens technology
UK II 1 G Ex ia IIC T3/T4/T6 GaEN TR 11/03/202415/01/202231/05/2021Dil:
İngilizce
Versiyon:
11/03/2024
Dosya boyutu:
492.9 KB
Dosya adı:
XA02553CEN_0324-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Memosens CLS15E, CLS16E, CLS21E, CLS82E
Supplement to: BA02018C, BA02019C, BA02020C and BA02027C
Safety instructions for electrical apparatus in explosion-hazardous
areas
JPN Ex ia IIC T3/T4/T6 GaEN TR 19/08/2021Dil:
İngilizce
Versiyon:
19/08/2021
Dosya boyutu:
488.3 KB
Dosya adı:
XA02686CEN_0121.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
XA Memosens CLS15E, CLS16E, CLS21E, CLS82E
Digital conductivity sensors with Memosens technology
KOR Ex ia IIC T6...T3 GaEN TR 25/03/202414/01/2022Dil:
İngilizce
Versiyon:
25/03/2024
Dosya boyutu:
488.9 KB
Dosya adı:
XA02802CEN_0224-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
XA Memosens CLS15E, CLS16E, CLS21E, CLS82E
Digital conductivity sensors with Memosens technology
ATEX: II 1 G Ex ia IIC T3/T4/T6 Ga
IECEx: Ex ia IIC T3/T4/T6 GaEN TR 13/03/202404/12/2020Dil:
İngilizce
Versiyon:
13/03/2024
Dosya boyutu:
496.2 KB
Dosya adı:
XA02080CEN_0224-00.pdf
-