Özelliklere genel bakış
-
Max. measurement error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) -
Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
-
Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional -
Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
-
Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Uygulama alanı
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
Full compliance according to NACE MR0175 and MR0103
Nominal diameter: DN 25 to 300 (1 to 12")
Medium temperature: –40 to 200 °C (–40 to 392 °F)
Device as compact or remote version
2-line backlit display with push buttons
HART, PROFIBUS PA, FOUNDATION Fieldbus
Avantajlar
Safe design for process industries – international hazardous area approvals
No additional pressure loss – full-bore design
Process transparency – diagnostic capability
Easy installation and reduced installation costs – loop-powered transmitter
Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
Automatic recovery of data for servicing
Videolar
Extended seçim
-
Üst düzey ürünler
- Son derece fonksiyonel ve uygun
Teknik mükemmellik
Sadelik
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri | Teknik mükemmellik | Sadelik |
---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
-
-
Teknik Bilgiler (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
İngilizce versiyonu - 11/2010
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN TR 05/11/201004/02/200901/06/2006Dil:
İngilizce
Versiyon:
05/11/2010
Dosya boyutu:
1.4 MB
Dosya adı:
TI00073DEN_1310.pdf
-
-
-
Kullanma Talimatı (BA)
Proline Prosonic Flow 92F Operating Instructions
İngilizce versiyonu - 11/2010
Ultrasonic Flow Measuring System
EN TR 05/11/201001/06/2006Dil:
İngilizce
Versiyon:
05/11/2010
Dosya boyutu:
3.5 MB
Dosya adı:
BA00121DEN_1310.pdf
-
-
-
Teknik Bilgiler (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN TR 05/11/201004/02/200901/06/2006Dil:
İngilizce
Versiyon:
05/11/2010
Dosya boyutu:
1.4 MB
Dosya adı:
TI00073DEN_1310.pdf
-
-
-
Kullanma Talimatı (BA)
Proline Prosonic Flow 92F FOUNDATION Fieldbus Operating Instructions
Ultrasonic Flow Measuring System
EN TR 08/11/201001/02/2008Dil:
İngilizce
Versiyon:
08/11/2010
Dosya boyutu:
3.3 MB
Dosya adı:
BA00128DEN_1310.pdf
-
-
-
Kullanma Talimatı (BA)
Prosonic Flow 92F PROFIBUS PA Operating Instructions
Ultrasonic Flow Measuring System, 2-Wire loop powered inline
flowmeterEN TR 11/11/201001/06/2006Dil:
İngilizce
Versiyon:
11/11/2010
Dosya boyutu:
3.6 MB
Dosya adı:
BA00122DEN_1310.pdf
-
-
-
Kullanma Talimatı (BA)
Proline Prosonic Flow 92F Operating Instructions
Ultrasonic Flow Measuring System
EN TR 05/11/201001/06/2006Dil:
İngilizce
Versiyon:
05/11/2010
Dosya boyutu:
3.5 MB
Dosya adı:
BA00121DEN_1310.pdf
-
-
-
Kısa Talimat (KA)
Proline Prosonic Flow 92F Brief Operating Instructions
Ultrasonic flow measuring system
Two-wire inline flowmeterEN TR 01/09/2009Dil:
İngilizce
Versiyon:
01/09/2009
Dosya boyutu:
550.4 KB
Dosya adı:
KA038DEN_0909.pdf
-
-
-
Kurulum talimatları (EA)
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN TR 15/10/202401/10/201828/06/2012Dil:
İngilizce
Versiyon:
15/10/2024
Dosya boyutu:
797.3 KB
Dosya adı:
EA00098DA2_1624-00.pdf
-
-
-
Kurulum talimatları (EA)
EA Installing sensor parts
Prosonic Flow 92F, Prowirl 72, 73, 200
EN TR 16/10/202301/09/201714/01/201628/11/2013Dil:
İngilizce
Versiyon:
16/10/2023
Dosya boyutu:
2 MB
Dosya adı:
EA01085DA2_0423-00.pdf
-
-
-
Kurulum talimatları (EA)
Repair kit cover remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65EN TR 01/10/201813/11/201418/04/2014Dil:
İngilizce
Versiyon:
01/10/2018
Dosya boyutu:
216.9 KB
Dosya adı:
EA01108DA2_0318.pdf
-
-
-
Kurulum talimatları (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN TR 01/03/201828/11/201325/04/2013Dil:
İngilizce
Versiyon:
01/03/2018
Dosya boyutu:
139.5 KB
Dosya adı:
EA01051DA2_0318.pdf
-
-
-
Kurulum talimatları (EA)
Replacing transmitter parts
Prowirl 72, 73, Prosonic Flow 92
EN TR 03/03/202001/04/201913/12/2010Dil:
İngilizce
Versiyon:
03/03/2020
Dosya boyutu:
451.5 KB
Dosya adı:
EA00043DA2_1520.pdf
-