Liquisys CCM253 is a standard chlorine transmitter with integrated pH compensation for free chlorine. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
The Liquisys CCM253 transmitter works with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors in:
Water & Wastewater - Disinfection process control and monitoring - Desalination with membrane technology - Swimming and whirl pools - Gas scrubbers
Food & Beverages - Disinfection of process water
Power plants - Cooling water disinfection
Liquisys CCM253 features the following protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP
PROFIBUS PA
Avantajlar
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Reliable chlorine and pH control: Current input for flow rate monitoring with controller shut off or for feedforward control.
Easy to operate and service: Intuitive user interface, simple calibration for chlorine and pH, direct access for manual contact control.
Reduced maintenance: Automatic cleaning function (with Chemoclean) triggered by alarm or limit switch.
Fit for every application: Numerous extensions, e.g. P(ID) controller, timer, etc., allow for flexible adaption to all processes.
Rotterdam, Botlek'teki AVR Waste, yılda 1,7 milyon tona kadar atık işliyor. Endress+Hauser sayesinde pH ölçümlerini nasıl optimize ettiklerini keşfedin
Endress+Hauser'in Viomax CAS51D dijital nitrat veya SAC sensörü ile Heineken'in Brezilya'da çevreyi korumak için tüm düzenlemeleri nasıl karşıladığını keşfedin.
Kalite gereksinimlerini karşılamak ve proseslerin kapsamlı bir şekilde izlenmesini sağlamak için akıllı dikey tarım tesislerinde pratik pH ve iletkenlik ölçümü.
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Tarayıcı deneyiminizi iyileştirmek, site işlevselliğini optimize etmek adına istatistikleri toplamak ve size uygun reklam ve içerikler göstermek için çerezleri kullanıyoruz.
"Tümünü kabul et" seçeneği ile çerez kullanımımıza rıza göstermiş olursunuz.
Daha fazla ayrıntı için lütfen göz atın: Çerez Politikamız .