Uygulama alanı
The Float switch FTS20 is a simple and cost-effective solution for point level detection in appropriate fluids. It is used in tanks and vessels as a pump protector or level alarm in open basins, e. g. in sewerage treatment plants. The float switch has two output options, a NAMUR switching signal or a change-over contact.
Point level switch for appropriate fluids. Used in tanks and vessels as an overfill prevention or as a pump protector. Different sensor/cable materials, e.g. PP, PVC, PUR and CSM, allow application in oily or aggressive liquids and hazardous areas.
Temperature: -20 to +85°C (-4 to +185°F)
Pressure: +3bar (+43.5psi)
International explosion protection certificates
Avantajlar
Reliable and cost-effective point level detection in liquids
Highest product and measurement safety due to different cable and sensor materials for different media
Electrical connections to NAMUR for hazardous areas (to Zone 1) or change-over contact (AC/DC) for universal standard application
Small diameter for simple installing using tapped hole G 1 A
Fundamental seçim
-
Basit ürünler
- Seçmesi, kurması ve çalıştırması kolay
Teknik mükemmellik
Sadelik
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri | Teknik mükemmellik | Sadelik |
---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
-
-
Kısa Talimat (KA)
Floating Switch FTS20 Technical Information and Operating Instructions
Point Level Switch for Liquids
EN TR 04/02/201907/05/201606/05/201612/09/201426/08/2011Dil:
İngilizce
Versiyon:
04/02/2019
Dosya boyutu:
2.1 MB
Dosya adı:
KA00180FA3_1719.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Liquifloat FTS20
II 2 G Ex ia IIB T5 Gb
EN TR 22/03/2021Dil:
İngilizce
Versiyon:
22/03/2021
Dosya boyutu:
354 KB
Dosya adı:
XA02429FEN_0121.pdf
-
-
-
Faaliyet Alanları (FA)
Level measurement
Product overview for applications in liquids and bulk solids
Dil:
İngilizce
Versiyon:
14/10/2022
Dosya boyutu:
10.5 MB
Dosya adı:
FA00001F00EN2522.pdf
-
-
-
Faaliyet Alanları (FA)
Misura di livello
Misura di livello
Panoramica dei prodotti per applicazioni in liquidi e solidi sfusiDil:
İtalyanca
Versiyon:
03/03/2023
Dosya boyutu:
46.9 MB
Dosya adı:
FA00001F00IT2522.pdf
-
-
-
Faaliyet Alanları (FA)
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Dil:
İspanyolca
Versiyon:
01/06/2022
Dosya boyutu:
7.2 MB
Dosya adı:
FA00001Fes Catalogo Nivel_24.22.pdf
-
-
-
Faaliyet Alanları (FA)
Füllstandsmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Dil:
Almanca
Versiyon:
14/10/2022
Dosya boyutu:
10.6 MB
Dosya adı:
FA00001F00DE2522.pdf
-
-
-
Yetkinlik Broşürü (CP)
Point level detection in liquids and bulk solids
Selection and engineering guide
Dil:
İngilizce
Versiyon:
27/08/2024
Dosya boyutu:
13.4 MB
Dosya adı:
CP00007F00EN1824.pdf
-
-
-
Yetkinlik Broşürü (CP)
Grenzstanddetektion in Flüssigkeiten und Schüttgütern
Auswahl- und Projektierungshilfe
Dil:
Almanca
Versiyon:
27/08/2024
Dosya boyutu:
13.8 MB
Dosya adı:
CP00007F00DE1824.pdf
-
-
-
Yetkinlik Broşürü (CP)
Catálogo soluciones esenciales
Alta calidad a precios competitivos
Dil:
İspanyolca
Versiyon:
16/01/2017
Dosya boyutu:
8.9 MB
Dosya adı:
CP01266Z.pdf
-
-
-
EU Beyan
Product family: Floating switch
Product root: FTS20-
Declaration number: TUEV01ATEX1709EN TR 10/09/2018Dil:
İngilizce
Versiyon:
10/09/2018
Dosya boyutu:
308.7 KB
Dosya adı:
EG-01033 f.pdf
-