Anahtar kelimelere, sipariş veya ürün koduna veya seri numarasına göre aramayı deneyin, örn. "CM442" veya "teknik bilgi"
Aramayı başlatmak için en az 2 karakter girin.
Source Container FQG60 - Radiometric measurement

Radiometric
Level/density measurement
Source Container FQG60

Radiation source container with radiation source insert with manual switch-on and switch-off

FQG60
Please Wait (spinning wheel)
Fiyat yükleniyor
Fiyatlar geçici olarak mevcut değil
Price on request
fiyat etkinleştiriliyor
fiyat: bilgi verin
Ölçüm görevini/uygulama görevini filtrele
Ölçüm / Uygulama görevi

Bu ürünün CAD çizimlerini indirmek için yapılandır

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    Approximately 18kg

  • Specialities

    With manual switch-on and switch-off

  • Ambient temperature

    –40...+120 °C
    (–40...+248 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    Approximately 18kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    –40...+120 °C
    (–40...+248 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    Approximately 18kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    –40 ...+120 °C
    (–40 ...+248 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    Approximately 18kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    –40...+120 °C
    (–40...+248 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Measuring principle

    Radiometric Density

  • Characteristic / Application

    Source container
    Emission angle: 5/ 20 / 40 degrees
    Approximately 18kg

  • Ambient temperature

    –40...+120 °C
    (–40...+248 °F)

  • Process temperature

    Any

  • Process pressure

    Any

  • Wetted parts

    Non-contact

  • Hygienic

    Non-contact

  • Specialities

    Control area calculation with Applicator