Özelliklere genel bakış
-
Process temperature
-40 °C ... 70 °C
(-40 °F ... 158 °F) -
Process pressure / max. overpressure limit
Vacuum ... 10 bar
(Vacuum ... 145 psi) -
Min. conductivity of medium
10 µS/cm
Uygulama alanı
The Liquipoint FTW32 offers simple and safe point level detection in conductive liquids. It offers numerous measuring possibilities due to multipoint detection (up to 5 rods).
For use in conductive liquids (as of 10μS/cm). For overfill prevention, dry running protection,
two-point control of pumps or multiple point detection.
Process connections: Threads
Sensor length: 0.25 to 15m (10 to 590")
Temperature: -40 to 70°C (-40 to 158°F)
Pressure: -1 to 10bar (-14.5 to 145psi)
International explosion protection certificates, overfill prevention and leakage detection certificate WHG
Avantajlar
Cost-effective probe for conductive liquids with detection of up to five point levels with one probe
No calibration required
Standard setting for the most common conductive liquids
No moving parts in the tank - long service life, reliable operation with no wear or blockages
Fundamental seçim
-
Basit ürünler
- Seçmesi, kurması ve çalıştırması kolay
Teknik mükemmellik
Sadelik
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
| FLEX seçimleri | Teknik mükemmellik | Sadelik |
|---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
Önceki seri
-
-
Teknik Bilgiler (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN TR 06/12/202425/03/202415/09/202328/10/202130/07/2021Dil:
İngilizce
Versiyon:
06/12/2024
Dosya boyutu:
1.3 MB
Dosya adı:
TI00426FEN_2624.pdf
-
-
-
Teknik Bilgiler (TI)
Liquipoint T FTW31, FTW32 Technical Information
Point level switch for multiple point detection in conductive liquids
EN TR 19/08/201609/04/201309/07/201001/07/2003Dil:
İngilizce
Versiyon:
19/08/2016
Dosya boyutu:
386.9 KB
Dosya adı:
TI00375FEN_1416.pdf
-
-
-
Kısa Talimat (KA)
Liquipoint T FTW 31, FTW 32
Level limit switch for multiple point detection in conductive liquids
without electronic insertEN TR 01/02/200501/07/2003Dil:
İngilizce
Versiyon:
01/02/2005
Dosya boyutu:
419.8 KB
Dosya adı:
KA203fa6.pdf
-
-
-
Kısa Talimat (KA)
KA Liquipoint T FTW32
İletken limit seviye ölçümü
EN TR 15/04/2024Dil:
Türkçe
Versiyon:
15/04/2024
Dosya boyutu:
338.2 KB
Dosya adı:
KA01712FTR_0124-00.pdf
-
-
-
Kısa Talimat (KA)
Liquipoint T FTW31, FTW32 Operating Information
Point level switch for multiple point detection in conductive liquids
EN TR 09/04/201309/07/201001/02/200501/07/2003Dil:
İngilizce
Versiyon:
09/04/2013
Dosya boyutu:
336.4 KB
Dosya adı:
KA00204FA6_1313.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
XA Liquipoint T FTW31, FTW32
Ex ia IIC T5 Gb
Ex ia [ia Ga] IIC T6 GbEN TR 30/07/2024Dil:
İngilizce
Versiyon:
30/07/2024
Dosya boyutu:
500 KB
Dosya adı:
XA02377FEN_0124-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Liquipoint T FTW31, FTW32
II 2 G Ex ia IIC Gb
II 2 G Ex ia [ia] IIC GbEN TR 28/02/202213/04/201631/12/201001/03/2003Dil:
İngilizce
Versiyon:
28/02/2022
Dosya boyutu:
399.5 KB
Dosya adı:
XA00230FEN_1521-00.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Liquipoint T FTW31, FTW32
Approval No.: EG 03 004-a
ATEX II 3 G
Protection:
EEx nA [L] IIC T6
EEx nC [L] IIC T6EN TR 01/02/2003Dil:
İngilizce
Versiyon:
01/02/2003
Dosya boyutu:
189 KB
Dosya adı:
XA226FA3.PDF
-
-
-
Ex Güvenlik Talimatı (XA)
Liquipoint T FTW31, FTW32
1Ex ia IIC T6 Gb
EN TR 03/08/2020Dil:
İngilizce
Versiyon:
03/08/2020
Dosya boyutu:
120.4 KB
Dosya adı:
XA02096FEN_0120.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Liquipoint T FTW31, FTW32
II 2 G Ex ia IIC Gb
II 2 G Ex ia [ia] IIC GbDil:
İngilizce
Versiyon:
28/03/2022
Dosya boyutu:
399 KB
Dosya adı:
XA02698FEN_0121-00.pdf
-