Anahtar kelimelere, sipariş veya ürün koduna veya seri numarasına göre aramayı deneyin, örn. "CM442" veya "teknik bilgi"
Aramayı başlatmak için en az 2 karakter girin.
Bioprocessing Raman spectroscopy calibration and verification kit for the Raman flow assembly

Raman calibration and verification kits

Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability

KRCAL
Please Wait (spinning wheel)
Fiyat yükleniyor
Fiyatlar geçici olarak mevcut değil
Price on request
fiyat etkinleştiriliyor
fiyat: bilgi verin
from CHF ??.-
Ölçüm görevini/uygulama görevini filtrele
Ölçüm / Uygulama görevi

Bu ürünün CAD çizimlerini indirmek için yapılandır

  • Measuring principle

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with bio multi optic)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • Measuring principle

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with Raman flow bench)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • Measuring principle

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-46

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm